Product information “IKI-50_1F R2”

Properties

The universal Feeder Control Unit IKI-50_1F R2 is the appropriate solution for intelligent distribution network stations and offers distribution network operators a high level of transparency and cost-effectiveness. The IKI-50_1F R2 includes all algorithms for selective fault detection. It is suitable for all neutral point treatments. Switching commands for load switch control can be fed to the IKI-50_1F R2 via communication bus and executed field-related with 1.5-pole switching safety. 

Fault detection

  • directional short-circuit detection
  • directional earth fault detection, directional static earth fault detection (wattmetric method), directional transient earth fault detection (wiper method), earth fault detection via pulse locating
  • suitable for all neutral point treatments
  • no summing transformer required

fault early detection

  • fault early detection by detection of transient disturbances
  • partial discharge trend detection together with CAPDIS-S2_55 (R5)

load flow measurement

  • voltages, Currents, powers, frequencies, cos-phi, . ..
  • Momentary and average values
  • Limit value monitoring

Remote control and network automation

  • selective control of up to two motors
  • extensive logic functions freely programmable with PC software KriesConfig

IKI- 50_F1 R2 is maintenance-free

  • no battery
  • unlimited data retention
  • error indication in case of power failure over 6 hours

precise voltage measurement with precision dividers

  • optional voltage measurement with precision dividers, z. E.g. resistive sensors
  • two voltage inputs: 1x capacitive, 1x resistive
  • patented method for voltage calibration via a reference measurement from another feeder
  • Product information “IKI-50_1F R2”

    Properties

    The universal Feeder Control Unit IKI-50_1F R2 is the appropriate solution for intelligent distribution network stations and offers distribution network operators a high level of transparency and cost-effectiveness. The IKI-50_1F R2 includes all algorithms for selective fault detection. It is suitable for all neutral point treatments. Switching commands for load switch control can be fed to the IKI-50_1F R2 via communication bus and executed field-related with 1.5-pole switching safety. 

    Fault detection

    • directional short-circuit detection
    • directional earth fault detection, directional static earth fault detection (wattmetric method), directional transient earth fault detection (wiper method), earth fault detection via pulse locating
    • suitable for all neutral point treatments
    • no summing transformer required

    fault early detection

    • fault early detection by detection of transient disturbances
    • partial discharge trend detection together with CAPDIS-S2_55 (R5)

    load flow measurement

    • voltages, Currents, powers, frequencies, cos-phi, . ..
    • Momentary and average values
    • Limit value monitoring

    Remote control and network automation

    • selective control of up to two motors
    • extensive logic functions freely programmable with PC software KriesConfig

    IKI- 50_F1 R2 is maintenance-free

    • no battery
    • unlimited data retention
    • error indication in case of power failure over 6 hours

    precise voltage measurement with precision dividers

    • optional voltage measurement with precision dividers, z. E.g. resistive sensors
    • two voltage inputs: 1x capacitive, 1x resistive
    • patented method for voltage calibration via a reference measurement from another feeder