Product information “IKI-Overhead R2”
Properties
With the IKI-Overhead R2, overhead lines can be easily monitored for faults and thus integrated into the overall protection concept to minimize downtime. Fault indication is provided locally via strong LEDs and optionally via remote transmission to a central control station.
Fault detection of all typical overhead line faults
Short circuits, transients and ground faults
Ultra-bright LED display
Visibility cone 360° , visible even in bright sunlight
Easy installation using actuating rod
Integrated torque indicator shows correct installation. No additional tools required.
Reliable fault detection
due to independent current/time characteristic [UMZ); short and earth [short] circuit detection; high impedance fault detection by dI/dT detection; inrush suppression; fault confirmation by monitoring for disconnection via integrated voltage sensor
Simple parameter setting by DIP switch
Response current (automatic or fixed thresholds 200 – 600 A). Reset time (2 – 8 h, manual or automatic after load current recovery). Access to DIP switches possible without tools.
Long life
due to high quality lithium battery, nanowatt technology and corrosion-free housing.
Easy installation
Torque indicator for safe mounting
.IKI-Overhead R2 with remote signalling: Radio and Butler versions
All communication elements are directly installed in the overhead line indicators. Therefore, no additional telecontrol unit mounted on the pole is required.
Easy connection to the control center via IEC 60870-5-104
With the optionally available SMS gateway, all installed IKI overhead R2 are connected to the control center or the PONLINE system and integrated
Detection of conductor breakage in the overhead line
Detection of conductor breakage without fault current
Transmission of load current values
Instantaneous or average values are transmitted cyclically
Remote parameterization of settings possible
Communication principle
Up to 8 IKI overhead radios communicate with one IKI overhead butler via short-range radio. The IKI overhead butler communicates via GSM with the PONLINE master server or any SMS receivers. The PONLINE master server can be connected to the control room via an IEC 60870-5-104 interface.
Principle of fault detection with remote signalling
Faults are detected and reported right up to the fault location in each case
Display of all relevant status information
In conjunction with PONLINE®, all important information (faults and load flow) from the overhead line network, such as all types of faults and load flow information, is recorded and transmitted.
IKI-Overhead R2
₹0.00
Properties
With the IKI-Overhead R2, overhead lines can be easily monitored for faults and thus integrated into the overall protection concept to minimize downtime. Fault indication is provided locally via strong LEDs and optionally via remote transmission to a central control station.
Fault detection of all typical overhead line faults
Short circuits, transients and ground faults
Ultra-bright LED display
Visibility cone 360° , visible even in bright sunlight
Easy installation using actuating rod
Integrated torque indicator shows correct installation. No additional tools required.
Reliable fault detection
due to independent current/time characteristic [UMZ); short and earth [short] circuit detection; high impedance fault detection by dI/dT detection; inrush suppression; fault confirmation by monitoring for disconnection via integrated voltage sensor
Simple parameter setting by DIP switch
Response current (automatic or fixed thresholds 200 – 600 A). Reset time (2 – 8 h, manual or automatic after load current recovery). Access to DIP switches possible without tools.
Long life
due to high quality lithium battery, nanowatt technology and corrosion-free housing.
Easy installation
Torque indicator for safe mounting
.
IKI-Overhead R2 with remote signalling: Radio and Butler versions
All communication elements are directly installed in the overhead line indicators. Therefore, no additional telecontrol unit mounted on the pole is required.
Easy connection to the control center via IEC 60870-5-104
With the optionally available SMS gateway, all installed IKI overhead R2 are connected to the control center or the PONLINE system and integrated
Detection of conductor breakage in the overhead line
Detection of conductor breakage without fault current
Transmission of load current values
Instantaneous or average values are transmitted cyclically
Remote parameterization of settings possible
Communication principle
Up to 8 IKI overhead radios communicate with one IKI overhead butler via short-range radio. The IKI overhead butler communicates via GSM with the PONLINE master server or any SMS receivers. The PONLINE master server can be connected to the control room via an IEC 60870-5-104 interface.
Principle of fault detection with remote signalling
Faults are detected and reported right up to the fault location in each case
Display of all relevant status information
In conjunction with PONLINE®, all important information (faults and load flow) from the overhead line network, such as all types of faults and load flow information, is recorded and transmitted.